1Phase 220V 2.2KW 3HP solar pump inverter solar vfd for irrigation

Model NO :
PH380-2S-2P2G-M
150-450VDC and 1phase 220VAC input 2.2KW 3HP 10A solar pump inverter for 220V single phase and 3phase water pumps, works stable and high efficiency
Quantity :
add to cart
Contact Now
 
PHAETO 1Phase 220V 2.2KW 3hp solar pump inverter 3hp solar vfd drivesolar vfd for irrigation 
Brand: PHAETON
Model No.: PH380-2S-2P2G
Input Voltage 150-450VDC, 1PHASE 220VAC
Output Voltage: Single phase or 3phase 220VAC
Rated Power: 2.2KW 3HP
Rated Current: 10A
Solar Panels selection: Voc 650VDC.
Motor selection: 220V 1hp to 3hp water pump.
Certificate: CE, IEC.
3hp solar pump inverter3hp solar pump inverter
The main features for PH380 series solar pump inverters:
1. Hybrid function to accept solar DC and grid AC input at same time, Grid AC automatic compensation.
2. Wide input voltage range:
     220V model: DC 150-450V ( DC 80-450V for 110V, 160V motor).
     380V model: DC 350-800V. 440V, 480V mode: DC 250-900V.
3. Drives well 220V single phase pump, 3phase pump.
4. Stable running and low frequency fluctuation.
5. All-round protection and inverter no burn.
6. Automatically start and stop function.
7. Adapt to various pumps, like AM, PMSM, submersible pump, surface pump etc.
 
Wiring explanation for water and dry run sensor:
 
(1) Connect 2 wires of float ball sensor to DI4 and COM for water tank level fulling detecting,
and set P4-03=51( float ball NO relay alarm). When water level reached to sensor detecting,
the normal open (NO) relay point will be activated, invereter will stop pumping, and sent a A.FuL alarm.
 
(2) Connect 2 wires of sensor of dry run sensor of well to DI5 and GND, and set P4-04=52 ( dry run NC relay alarm).
It will sent alarm A.LLd and stop pumping when lack of water in well for dry run protection.
 
(3) It is also enable to connect analog ( 0-10VDC, or 0/4-20mA) water level sensor for water tank leveling detecting.
 
(4) Connecting 2 wires of 0/4-20mA analog sensor to AI1 and 24VDC terminals of inverter,
and short connect COM and GND terminals for constructing a loop circuit.
 
3hp solar pump inverter
 
PHAETON PH380 solar pump inverter Model Number:
 S.N.  Model NumberCurrent (A)Voltage (V)Power (KW)Measurement (MM)Suggest
VOC (VDC)
G.W. 
(Kg)
PH380-2S series: 150-450VDC, 1phase 220VAC input, 1/3phase 220VAC output
1PH380-2S-1P5G-M7A0-250VAC1.5KW185*118*153.8260 to 3752
2PH380-2S-2P2G-M10A0-250VAC2.2KW185*118*153.8260 to 3752
3PH380-2S-004G17A0-250VAC4.0KW247*160*175260 to 3754
4PH380-2S-5P5G25A0-250VAC5.5KW247*160*175260 to 3754
 PH380-4T series: 250-800V/900VDC input, 3phase 0-380V,440/480VAC output
1PH380-4T-2P2G-M7A0-480VAC2.2KW185*118*153.8486 to 7502
2PH380-4T-004G10A0-480VAC4KW185*118*153.8486 to 7503
3PH380-4T-5P5G13A0-480VAC5.5KW247*160*175486 to 7504
4PH380-4T-7P5G17A0-480VAC7.5KW247*160*175486 to 7504
5PH380-4T-011G25A0-480VAC11KW247*160*175486 to 7504.5
6PH380-4T-015G32A0-480VAC15KW320*220*197.3486 to 7507
7PH380-4T-018G37A0-480VAC18KW320*220*197.3486 to 7507.5
8PH380-4T-022G45A0-480VAC22KW320*220*197.3486 to 7507.5
9PH380-4T-030G60A0-480VAC30KW480*260*215486 to 75017
10PH380-4T-037G75A0-480VAC37KW480*260*215486 to 75017
11PH380-4T-045G91A0-480VAC45KW575*320*310486 to 75035
12PH380-4T-055G110A0-480VAC55KW575*320*310486 to 75036
13PH380-4T-075G150A0-480VAC75KW620*380*310486 to 75045
14PH380-4T-093G180A0-480VAC93KW620*380*310486 to 75048
15PH380-4T-110G220A0-480VAC110KW620*380*310486 to 75050
16PH380-4T-132G250A0-480VAC132KW620*380*310486 to 75050
17PH380-4T-160G310A0-480VAC160KW817*500*348486 to 75094
18PH380-4T-185G340A0-480VAC185KW817*500*348486 to 75095
19PH380-4T-200G380A0-480VAC200KW817*500*348486 to 75096
20PH380-4T-XXXG415-800A0-480VAC220-450KW1200*600*450486 to 750150
PH380-4T-450G